*THÔNG SỐ ĐẶC TÍNH CƠ BẢN:
Input |
Input voltage | 1AC 220V±15%,3AC 220V±15%,3AC 380V±15%,3AC 660V±15% | ||||||
Input frequency | 47~63Hz | |||||||
Output | Output voltage | 0~Rated voltage | ||||||
Output frequency | V/f contol:0~3000Hz SVC:0~300Hz | |||||||
Control Feature |
Control mode | V/f , SVC, Torque control | ||||||
Operation command mode | Keypad control, Terminal control, Serial communication control | |||||||
Frequency setting mode | Digital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combinated & switched in various modes. | |||||||
Overload capacity | G model: 150% 60s, 180% 10s, 200% 3s
P model: 120% 60s, 150% 10s, 180% 3s |
|||||||
Starting torque | 0.5Hz/150% (SVC),1Hz/150% (V/f) | |||||||
Speed adjustment range | 1:100 (SVC),1:50(V/f) | |||||||
Speed control precision | ±0.5%(SVC) | |||||||
Carrier frequency | 1.0–16.0kHz, automatically adjusted according to temperature and load characteristics | |||||||
Frequency accuracy | Digital setting: 0.01Hz
Analog setting: maximum frequency ×0.05% |
|||||||
Torque boost | Automatically torque boost; manually torque boost : 0.1%~30.0% | |||||||
V/f curve | Three types: straight line, multiple point and square type(1.2 power, 1.4 power, 1.6 power, 1.8 power, square) | |||||||
ACC/DEC mode | Linear/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s | |||||||
DC braking | DC braking when starting and stopping
DC braking frequency: 0.0Hz~maximum frequency, braking time: 0.0s~100.0s |
|||||||
Jog operation | Jog operation frequency: 0.0Hz~maximum frequency
Jog acceleration/deceleration time: 0.1s~3600.0s |
|||||||
Simple PLC & multi-step speed operation | Max. 16 steps speed running via built-in PLC or control termina | |||||||
Built-in dual PID | Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.) | |||||||
Automatic voltage regulation | Keep output voltage constant automatically when input voltage fluctuating | |||||||
Control |
Common DC bus | Common DC bus for several inverters, energy balanced automatically | ||||||
Torque control | Torque control without PG | |||||||
Torque limit | Rooter” feature: limit torque automatically and prevent frequent over-current tripping when running | |||||||
Wobble frequency control | Multiple triangular-wave frequency control, special for spinning | |||||||
Timing/length/counting control | Timing/length/counting control function | |||||||
Over-voltage & over currentstall control |
Limit current & voltage automatically when running, prevent frequent over-current & over-voltage tripping | |||||||
Fault protection function | Up to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure and has fault automatic reset function | |||||||
Terminals |
Input terminals | Programmable DI: 7 on-off inputs,
1 high-speed pulse input 2 programmable AI: AI1: voltage -10~10V A12: voltage 0~10V or current 0/4~20mA |
||||||
Output terminals | 1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output)
2 relay outputs 2 analog output: 0/4~20mA or 0~10V |
|||||||
Communication terminal | Offer RS485 communication interface, support MODBUS-RTU communication protocol | |||||||
Human Interface |
LED display | Display frequency setting, output frequency, output voltage, output current, etc. | ||||||
Multifunction key | QUICK/JOG key, can be used as multifunction key | |||||||
Powerful host software | Support upload, download and real time display between inverter and PC | |||||||
Enviorment |
Ambient temperature | -10℃~40℃, derated 4% when the temperature rise by each1℃ (40℃~50 ℃). | ||||||
Humidity | 90%RH or less (non-condensing) | |||||||
Altitude | ≤1000M: output rated power, >1000M: output derated | |||||||
Storage temperature | -20℃~60℃ | |||||||
Storage atmosphere | Indoor, without direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip, salt, vibration, etc. |